Regulating Valve
第1题:
what is Cisco provides three mechanisms for regulating or shaping traffic?
第2题:
the direct acting relief valve is used for controlling lower flows and pressure
the pilot operated relief valve is used for controlling higher flows and pressure
the pilot operated relief valve is used for controlling lower flows and pressure
the controlling accuracy of direct acting relief valve is worse than that of the pilot operated relief valve
第3题:
expansion valve to overfeed
compressor to knock
water regulating valve to fail
crankcase drains to plug
第4题:
the pressure regulating valve is not closing
an excessive lack of refrigerant in the system
badly leaking discharge valves
worn piston rings
第5题:
第6题:
gate valve
globe valve
swing-check valve
plug-cock valve
第7题:
fuel supply
firing order
engine load
oil level
第8题:
evaporator pressure decrease
evaporator coil over-feed
evaporator capacity increase
expansion valve diaphragm rupture
第9题:
discharge service valve as a vapor
suction service valve as a liquid
charging valve as a liquid
condenser purge valve as a vapor
第10题:
change the expansion valve adjustment
readjust the water regulating valve to increase the flow of water
purge air from the condenser
clean the waterside of the condenser
第11题:
expansion valve to the compressor
receiver to the expansion coil
expansion valve to the evaporator
condenser to the expansion valve
第12题:
one valve seats upwards, while the other seats downwards
the reed valves used on the discharge are made substantially thicker and heavier than the suction valves
the suction valve springs exert a greater tension than the discharge valve springs
the discharge valve springs exert a greater tension than the suction valve springs
第13题:
the inlet valve is open
the exhaust valve is open
both valves are close
both valves are open
第14题:
break glass,pull valve,break glass,pull cylinder control
sound evacuation alarm,pull handle
open bypass valve,break glass,pull handle
open stop valve,open control valve,trip alarm
第15题:
The globe valve may be suitable for partially open operation
The globe valve will give full bore flow with change of direction
The gate valve gives full bore flow with change of direction
The gate valve is suitable for full bore operation only
第16题:
the relief valve should open before the high pressure cutout
the relief valve should open and allow the excess refrigerant to flow to the receiver
the high pressure cutout switch should operate before the relief valve opens
you should close in on the suction valve
第17题:
第18题:
the relief valve should open before the high-pressure cutout
the relief valve should open and let excess refrigerant go to receiver
the high-pressure cutout switch should operate before the relief valve opens
close in on the suction valve
第19题:
clearance between the top of the valve stem and the rocker arm
compression of the valve springs
clearance between the valve seat inserts and the head
out of roundness of the fuel injection cams
第20题:
suction service valve as a vapor
suction service valve as a liquid
discharge service valve as a vapor
charging valve as a liquid
第21题:
worn valve seats
worn main bearing
excessive valve clearance
weak rocker arm springs
第22题:
box temperature solenoid valve will close
expansion valve will close
compressor will shutdown
king valve will open
第23题:
reduce wear on the valve stem
permit the use of alloy valve seat materials
reduce heat transfer from the valve seat
facilitate valve removal for servicing