A system has a TCPIP issue that is a known problem. The newest code from the support website has been downloaded to resolve the issue. Which of the following commands should be used to install the new code?()
第1题:
A system administrator did not receive a response while attempting to ping loopback. Which of the following would most likely resolve this problem?()
第2题:
An administrator logs into a server and notices slow performance. When the system finishes the logon process a message is displayed saying the system is out of Virtual Memory. Which of the following is the MOST likely cause of this issue?()
第3题:
An administrator is troubleshooting a problem on an application server, but has not determined the cause of the problem and is not able to replicate the problem. Which of the following should the administrator do prior to escalating the issue?()
第4题:
A blade server has been configured to boot from SAN. After an HBA firmware upgrade the blade was rebooted and cannot find the operating system. Which of the following should the administrator do NEXT to troubleshoot the issue?()
第5题:
Which command must be run after an administrator has made changes to /etc/services to activate the changes?()
第6题:
It is a hardware problem caused by the power failure.
There is a network problem, most probably with name resolution.
Sine the system was never rebooted, devices are marked defined instead of available and need to be activated.
Some filesets may be marked as broken and need to be reinstalled.
第7题:
adding small amounts of oil to the system
the system has been overheated
the system has been drained and then filled with new oil
the system has been idle for a long period of time
第8题:
CATALOG TCPIP NODE myhost REMOTE db2srv SERVER 446
CATALOG TCPIP NODE mydb2srv REMOTE myhost SERVER 446
CATALOG TCPIP NODE myhost REMOTE db2srv SERVER 192.168.10.1
CATALOG TCPIP NODE mydb2srv REMOTE myhost SERVER 192.168.10.1
第9题:
The system has a fragmented hard drive.
The drive interface needs to be changed.
The user has too many documents on the hard drive.
The system page file has an issue.
第10题:
The drives have been configured as basic.
The system partition with the page file is out of space.
The VMFS has bad sectors.
The drivers for the memory have become corrupt.
第11题:
Test the theory to determine if the solution will correct the issue, list all other possible causes.
Verify full system functionality.
Document the issue; include details regarding findings, actions taken to resolve the issue, and the outcome.
Establish a theory of probable cause based on previous tests and determine next steps toresolve
第12题:
a, c, f, g
b, d, e, h
a, b, c, f, g
d, a, e, g
b, c, f, e, g
第13题:
A system powers on, begins POST, displays the BIOS version information and then hangs with the error message ‘Error loading operating system’. Which of the following is MOST likely the cause of this issue? ()
第14题:
A technician is troubleshooting a workstation that has the wrong time information. All workstations should be pointing to a central NTP server. Which of the following locations would the technician check to investigate error messages related to this issue?()
第15题:
A system powers on, begins POST, displays the BIOS version information and then hangs with the error message Error loading operating system. Which of the following is MOST likely cause of this issue? ()
第16题:
An end user reports that their computer is making noise constantly. The technician notes that the hard drive activity light is on frequently. The technician finds plenty of free space on the drive.Which of the following BEST explains why the drive light is continuously active?()
第17题:
An AIX server has 2 network interfaces and it needs to be permanently configured as a gateway. How can this be accomplished?()
第18题:
Private issue has always been associated with data collection.
Attacks on freedom are new.
The accumulation of data encourages oppression.
Privacy has been a neglected issue.
第19题:
smitty install_commit
installp -ugV
installp -aX
instfix -all
第20题:
request system software replace
request system software install
request system software add
request system software upgrade
第21题:
power cycle the system completely.
run an on-demand virus scan.
perform a system restore.
check the installation event logs
第22题:
Gather information from users.
Reboot the server.
Apply the latest service packs to the operating system.
Perform a root cause analysis
第23题:
A virus has infected the system
Corrupted BOOT.INI file
Corrupt MBR
Boot sector corruption
第24题:
2.4GHz
900MHz
1.1GHz
5GHz