An administrator recently installed a new array controller into a server. When the server is running POST the controller does not appear as present. Which of the following could be the reason for this?()
第1题:
An administrator has just upgraded a server from non-hot plug storage to all hot plug storage. The administrator powers up the server, during POST the RAID controller is recognized but none of the drive lights flash. Which of the following should the administrator do FIRST to troubleshoot the problem?()
第2题:
An administrator wants to rackmount a new server. Power and network outlets are available and cooling in the room is adequate to support the additional server. The new server is identical to the other servers already installed. Which of the following items should the administrator FIRST verify before installing the server?()
第3题:
An administrator attempts to install the latest security patches for an older server. When the administrator runs the patch installer, the install fails. The administrator tries again, and the installer fails again. Which of the following is the MOST likely reason for this?()
第4题:
An administrator has just installed a web server for the company's Internet site. After bringing the system online, customers notify the administrator that they cannot connect to the server. The administrator tests the web server from a workstation and can access the website. The customers continue to report issues. Which of the following is the MOST likely reason for this?()
第5题:
A new array of hard drives has been added to an existing server; however, when the server is booted into the Windows OS the new drives fail to appear in My Computer. From which of the following locations can the new storage drives be added?()
第6题:
After installing a second processor and corresponding heatsink into a server, an administrator notices that the new processor is not showing up during POST. Which of the following could be the cause of this issue?()
第7题:
A technician installs a SATA controller card and moves the hard drive cable from the system board to the SATA controller. The system POSTs and the controller BIOS recognizes the hard drive but does not boot to the hard drive and start Windows. Which of the following is the MOST likely cause of the problem?()
第8题:
the server vendor’s FAQ website
the SCSI controller vendor’s user manual
the drive enclosure vendor’s user manual
the network operating system vendor’s website
第9题:
The power supply is not sufficient to power the server.
The voltage regulator module (VRM) was not installed.
The IRQ setting was not set.
The DMA setting was not set.
第10题:
Update the time and date in the BIOS.
Update the firmware on the SCSI controller.
Update the firmware to the latest version.
Configure IPMI on the new board.
第11题:
Incompatible memory
Memory failure
The memory is not configured
The server BIOS was not configured to accept the additional memory
第12题:
The hard drives were not plugged into the server correctly.
The controller driver is outdated and needs to be updated from the OEMs website.
The firmware for the server is too old and does not support the new RAID controller card.
The cable from the controller to the hard drive backplane is not connected.
第13题:
An administrator notes that after a recent power outage, some open files were corrupted on one affected file server. Which of the following items should the administrator consider to determine the cause of this corruption?()
第14题:
An administrator just installed a new RAID controller card into a server. The firmware is current for the controller card. When the server is powered up the administrator notices that the RAID controller card is not recognized during POST. Which of the following is the cause of the problem?()
第15题:
An administrator has just installed a new NIC into the server. The system POSTs fine and the NIC is recognized by the OS, but it does not receive an IP address. Which of the following is the MOST likely cause of this?()
第16题:
Two new servers are purchased and need to be installed to allow sharing of a single external hard drive enclosure. One server is configured as a local file server, and the other as a database server for a different network. The onsite technician notices that when both servers are running at the same time, they each receive SCSI errors. When they are running individually, no errors are reported. Which of the following is the BEST source of information to use for troubleshooting this problem?()
第17题:
An administrator has just finished physically replacing the system board in a Windows domain controller. Which of the following must be done before booting the server back into Windows?()
第18题:
The administrator has just installed a new memory module into the server. Now, the server is not showing the new memory. Which of the following should the administrator perform FIRST?()
第19题:
The administrator improperly configured the virtual memory settings on the server.
The administrator is using incorrect patch switches for the install.
The administrator is trying to install security patches for software that is not installed.
The administrator is trying to install patches that require hard drive encryption on the server.
第20题:
The server BIOS firmware is out-of-date.
The server does not have the correct drivers.
The server hard drives have not begun to spin.
The server has too little memory installed.
第21题:
The server BIOS firmware is out-of-date.
The server does not have the correct drivers.
The server hard drives have not begun to spin.
The server has too little memory installed.
第22题:
Format command
Hypervisor
Computer Management
Disk Management
Virtual Center
第23题:
The server's memory
The server's RAID controller battery
The server's processor
The server's NIC teaming configuration