A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()
第1题:
An administrator is building a server that will run a data warehousing application.The server was ordered with eight 300GB drives.The application requires a dedicated storage location for the OS and one for critical files.The critical file storage needs fast access but must provide high redundancy.The OS requires 100GB and the file requires 950GB.Which of the following configurations will BEST suit the data warehouse needs?()
第2题:
A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status?()
第3题:
An administrator setting up software RAID 1 on a Windows Server with two volumes for twoseparate hard drives, but the option for mirrored is grayed out. Which of the following is the MOST likely reason why this is occurring?()
第4题:
Which of the following offers the MOST redundancy for a system but is also very costly? ()
第5题:
An administrator installs a new server with five 146GB drives and implements RAID 5 for hardware redundancy.How much disk space will be available for the OS, tools and regular files?()
第6题:
A new array of hard drives has been added to an existing server; however, when the server is booted into the Windows OS the new drives fail to appear in My Computer. From which of the following locations can the new storage drives be added?()
第7题:
A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline. Which of the following components would MOST likely have caused the problem?()
第8题:
A customer has a need for an xSeries server for an application requiring 12GB memory with the capacity of up to 20GB. The HDD configuration needs to be as follows: (1)Two drives RAID-1 for the operating system (2)Five drives for Data in a RAID-5 configuration with one Hot-Spare (3)All drives have to be internal. Which of the following will satisfy the requirements for the application?()
第9题:
RAID implementation
Disk-to-disk replication
Server-to-server clustering
Hot site replication
第10题:
Memory
SCSI backplane
SCSI drives
Motherboard
第11题:
Memory
SCSI backplane
SCSI drives
Motherboard
第12题:
288GB
360GB
432GB
728GB
第13题:
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()
第14题:
An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array. When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()
第15题:
A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()
第16题:
A server crashed because it ran out of all free available disk space. After booting the server backup it is noticed that enhanced logging was enabled on the web server software months before. Which of the following is MOST likely causing the disk to run out of space? ()
第17题:
A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status? ()
第18题:
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()
第19题:
An xSeries specialist monitors a customer’s server that has poor performance. The customer is running an x365 with a ServeRAID 6i controller with write-back cache turned on and ten 15K rpm drives in a RAID-5 array. It is a mission-critical server and must have a redundant storage system. Performance tests indicate that the Average Disk sec/Transfer exceeds 20 ms. Which of the following is the lowest-cost method to increase the throughput?()
第20题:
x366
x255
x346
x455
第21题:
OS:3 Drives,RAID 1 with hot spare;Files:5 Drives,RAID 5 with hot spare
OS:2 Drives,RAID 1;Files:6 Drives,RAID 1
OS:2 Drives,RAID 0;Files:6 Drives,RAID 5
OS:2 Drives,RAID 1;Files:6 Drives,RAID 5 with hot spare
第22题:
Break mirror array
Replace cache battery
Replace hot standby
Restore from backup
Replace defective hard drives
第23题:
The web server requires larger disk drives.
Traffic to the web server has increased.
Disks are not large enough for the web server software.
Log files are filling the disk.