单选题A system administrator has added a new graphics card to the system and rebooted. The system pauses with C31 in the three-digit displays. Which of the following causes could be the reason for the hang?()A All filesets for CDE have not been loaded. Boot

题目
单选题
A system administrator has added a new graphics card to the system and rebooted. The system pauses with C31 in the three-digit displays. Which of the following causes could be the reason for the hang?()
A

All filesets for CDE have not been loaded. Boot into maintenance mode and load them through SMIT.

B

There is a missing device driver, incorrect console configuration, or a serial device plugged into native S1 port.

C

The new graphics adapter card is marked defined, not available. Rum smit cfgmgr (Install/Configure Devices Added After IPL with the INPUT device /directory for software set to none). This will reconfigure all devices by walking the bus.

D

The LED C31 means that there is a corrupted /dev/hd5. Boot into maintenance mode, fsck /dev/hd5 and then issue the bosboot command.


相似考题
更多“单选题A system administrator has added a new graphics card to the system and rebooted. The system pauses with C31 in the three-digit displays. Which of the following causes could be the reason for the hang?()A All filesets for CDE have not been loaded. Boot ”相关问题
  • 第1题:

    Which of the following could the system administrator use to assist in debugging boot problems after the system is up?()

    • A、SMS
    • B、alog
    • C、fsck
    • D、bosboot

    正确答案:B

  • 第2题:

    A server technician has been attempting to install an operating system on the company test server for several days. The technician has experienced error messages at several points of theinstallation and the system has frozen during various parts of the boot process. The technician has replaced the power supply, graphics card and installation disk with known good components.Which of the following could be causing these issues?()

    • A、Storage driver not loaded
    • B、Fragmented hard drive
    • C、Damaged or faulty NIC chipset
    • D、Damaged or faulty system board
    • E、Memory incompatible with the processor
    • F、Missing voltage regulator

    正确答案:D,E

  • 第3题:

    An administrator adds a new SATA hard drive into a functional server and attempts to boot the server. The server will no longer boot into the operating system. The administrator checks all the connections and reboots the server. The server still will not load the operating system.  Which of the following is the MOST probable cause?()

    • A、The BIOS is set with the wrong boot order.
    • B、The jumpers have not been set on the hard drive.
    • C、The hard drive is not compatible with the system board.
    • D、The boot.ini file needs to be modified.

    正确答案:A

  • 第4题:

    A System p administrator has been instructed to verify that all filesets have all required requisitesand are completely installed. Which of the following commands will provide this information()

    • A、lslpp
    • B、lppchk
    • C、geninstall
    • D、installp

    正确答案:B

  • 第5题:

    A new application has been added to a system which needs to automatically be started at system startup. The system administrator has decided to accomplish this by using the /etc/inittab file. Which command would be used to accomplish this in a supported manner?()

    • A、vi
    • B、mkitab
    • C、telinit
    • D、startsrc

    正确答案:B

  • 第6题:

    多选题
    A server technician has been attempting to install an operating system on the company test server for several days. The technician has experienced error messages at several points of theinstallation and the system has frozen during various parts of the boot process. The technician has replaced the power supply, graphics card and installation disk with known good components.Which of the following could be causing these issues?()
    A

    Storage driver not loaded

    B

    Fragmented hard drive

    C

    Damaged or faulty NIC chipset

    D

    Damaged or faulty system board

    E

    Memory incompatible with the processor

    F

    Missing voltage regulator


    正确答案: D,A
    解析: 暂无解析

  • 第7题:

    单选题
    A graphics card has been added and the system rebooted. When running the lsdev-Cc adapter, the graphics card is not listed in the output. Which of the following actions should be performed?()
    A

    Reboot system sing the mkdev -l command.

    B

    Install device support suing the cfgmgr -i command.

    C

    Use the SMIT console to redirect the console.

    D

    Use SMIT devices and choose the correct adapter.


    正确答案: B
    解析: 暂无解析

  • 第8题:

    单选题
    A System p administrator has just installed a new technology level, but "oslevel -r" does not show the expected technology level.  Which of the following commands would determine which filesets are downlevel()
    A

    lppchk

    B

    instfix

    C

    oslevel

    D

    installp


    正确答案: C
    解析: 暂无解析

  • 第9题:

    单选题
    A blade server has been configured to boot from SAN.  After an HBA firmware upgrade the blade was rebooted and cannot find the operating system.  Which of the following should the administrator do NEXT to troubleshoot the issue?()
    A

    Verify all HBA settings.

    B

    Upgrade the blade firmware.

    C

    Upgrade the OS level HBA drivers.

    D

    Set the system to boot from the local disk.


    正确答案: C
    解析: 暂无解析

  • 第10题:

    单选题
    A system administrator has been instructed to verify that all filesets have all required requisites and are completely installed. Which command will provide this information?()
    A

    lslpp

    B

    lppchk

    C

    instfix

    D

    installp


    正确答案: B
    解析: 暂无解析

  • 第11题:

    单选题
    Which of the following could the system administrator use to assist in debugging boot problems after the system is up?()
    A

    SMS

    B

    alog

    C

    fsck

    D

    bosboot


    正确答案: C
    解析: 暂无解析

  • 第12题:

    单选题
    An administrator has added a new device to a system and wants to determine if it has been correctly added to the ODM database. Which command would the system administrator use?()
    A

    odmget

    B

    odmadd

    C

    odmshow

    D

    odmcreate


    正确答案: D
    解析: 暂无解析

  • 第13题:

    A graphics card has been added to the system. After rebooting, the system hangs during the login process with a blue screen indicating "CDE please wait". Which of the following procedures should be performed next?()

    • A、Reinstall the CDE software
    • B、Check the name resolution
    • C、Uncomment the last line in .dtprofile
    • D、Boot in maintenance mode and perform fsck on file systems

    正确答案:A

  • 第14题:

    A blade server has been configured to boot from SAN.  After an HBA firmware upgrade the blade was rebooted and cannot find the operating system.  Which of the following should the administrator do NEXT to troubleshoot the issue?()

    • A、Verify all HBA settings.
    • B、Upgrade the blade firmware.
    • C、Upgrade the OS level HBA drivers.
    • D、Set the system to boot from the local disk.

    正确答案:A

  • 第15题:

    A graphics card has been added and the system rebooted. When running the lsdev-Cc adapter, the graphics card is not listed in the output. Which of the following actions should be performed?()

    • A、Reboot system sing the mkdev -l command.
    • B、Install device support suing the cfgmgr -i command.
    • C、Use the SMIT console to redirect the console.
    • D、Use SMIT devices and choose the correct adapter.

    正确答案:B

  • 第16题:

    A System p administrator has just installed a new technology level, but "oslevel -r" does not show the expected technology level.  Which of the following commands would determine which filesets are downlevel()

    • A、lppchk
    • B、instfix
    • C、oslevel
    • D、installp

    正确答案:B

  • 第17题:

    A system administrator has added a new graphics card to the system and rebooted. The system pauses with C31 in the three-digit displays. Which of the following causes could be the reason for the hang?()

    • A、All filesets for CDE have not been loaded. Boot into maintenance mode and load them through SMIT.
    • B、There is a missing device driver, incorrect console configuration, or a serial device plugged into native S1 port.
    • C、The new graphics adapter card is marked defined, not available. Rum smit cfgmgr (Install/Configure Devices Added After IPL with the INPUT device /directory for software set to none). This will reconfigure all devices by walking the bus.
    • D、The LED C31 means that there is a corrupted /dev/hd5. Boot into maintenance mode, fsck /dev/hd5 and then issue the bosboot command.

    正确答案:B

  • 第18题:

    单选题
    The system administrator did a new install of AIX on a server about a week ago. The system was not rebooted after the installation. CDE is running on this system as is TCPIP. The system administrator has started configuring the system percompany directives. The power cable was inadvertently disconnected from the wall causing the sever to lose power. Upon reboot, the system appears to hang during log in from the console or from Xterminals. Which of the following is the most probable cause?()
    A

    It is a hardware problem caused by the power failure.

    B

    There is a network problem, most probably with name resolution.

    C

    Sine the system was never rebooted, devices are marked defined instead of available and need to be activated.

    D

    Some filesets may be marked as broken and need to be reinstalled.


    正确答案: C
    解析: 暂无解析

  • 第19题:

    单选题
    A graphics card has been added to the system. After rebooting, the system hangs during the login process with a blue screen indicating "CDE please wait". Which of the following procedures should be performed next?()
    A

    Reinstall the CDE software

    B

    Check the name resolution

    C

    Uncomment the last line in .dtprofile

    D

    Boot in maintenance mode and perform fsck on file systems


    正确答案: D
    解析: 暂无解析

  • 第20题:

    单选题
    A System p administrator has been instructed to verify that all filesets have all required requisitesand are completely installed. Which of the following commands will provide this information()
    A

    lslpp

    B

    lppchk

    C

    geninstall

    D

    installp


    正确答案: A
    解析: 暂无解析

  • 第21题:

    单选题
    A system administrator has added a new port entry in /etc/services for a new application to be tested. Which of the following commands should be used to activate this port?()
    A

    telinit -q

    B

    refresh -s inetd

    C

    startsrc -g services

    D

    refresh -s portmap


    正确答案: A
    解析: 暂无解析

  • 第22题:

    单选题
    An administrator adds a new SATA hard drive into a functional server and attempts to boot the server. The server will no longer boot into the operating system. The administrator checks all the connections and reboots the server. The server still will not load the operating system.  Which of the following is the MOST probable cause?()
    A

    The BIOS is set with the wrong boot order.

    B

    The jumpers have not been set on the hard drive.

    C

    The hard drive is not compatible with the system board.

    D

    The boot.ini file needs to be modified.


    正确答案: A
    解析: 暂无解析

  • 第23题:

    单选题
    A new application has been added to a system which needs to automatically be started at system startup. The system administrator has decided to accomplish this by using the /etc/inittab file. Which command would be used to accomplish this in a supported manner?()
    A

    vi

    B

    mkitab

    C

    telinit

    D

    startsrc


    正确答案: A
    解析: 暂无解析