SVC software that comes integrated in an XIV system
SVC option that includes all functions of SVC at a 'per TB' charge
SVC option that introduces a 'per enclosure' charge metric for all functions of SVC
separate license available for XIV/SVC customers who need FlashCopy and Metro Mirror/Global Mirror functions
第1题:
说明PVC和SVC的区别,以及建立SVC的过程。
第2题:
A customer is planning to purchase an IBM N series Gateway due to a requirement for file levelstorage. All available storage is managed by a SAN Volume Controller (SVC). Where should the Nseries Gateway be placed in the network?()
第3题:
A customer has a wide range of IBM enterprise disk systems and wants to manage copy services functions. Which of the products should the storage specialist recommend to this customer()
第4题:
A large shipping company that is standardized on Fibre Channel storage has just acquired a regional shipping company that is using an IBM XIV system. The large company would like to integrate the XIV system into the environment and manage all data through a single management interface. Which product should be suggested so that all data can be managed?()
第5题:
A local manufacturing customer is looking for a highly scalable, easy to use disk storage system tosupport a new application they are bringing into the data center. The customer has an initialrequirement for 40 TB of high performance storage but they expect to more than double thecapacity needed once the application goes into full production. What IBM solution would be themost cost effective while meeting their initial requirements?()
第6题:
When your Solaris system is booted, a startup script initializes the rpcbind service. Which script is it? ()
第7题:
SVC software that comes integrated in an XIV system
SVC option that includes all functions of SVC at a 'per TB' charge
SVC option that introduces a 'per enclosure' charge metric for all functions of SVC
separate license available for XIV/SVC customers who need FlashCopy and Metro Mirror/Global Mirror functions
第8题:
IBM DS8700
IBM XIV GUI
IBM System Storage N7600
IBM SAN Volume Controller (SVC)
第9题:
is stateless with global referencing of metadata
is based on cluster architecture with externally provided quorum disks
is based on cluster architecture, with quorum held internally on the first cluster node
is based on grid architecture, with each node holding a full mirror configuration for all other nodes
第10题:
/lib/svc/method/net-physical
/etc/rcS.d/S30network
svc:/network/rpc/bind:default
/lib/svc/method/rpc-bind
第11题:
LES
BUS
LECS
ARP server
第12题:
zoning is typically limited to controlling access to physical storage
zoning is focused on access control between SVC nodes and host systems
zoning is focused on access to physical storage arrays, SVC clusters, and hosts
zoning is focused on the access relationship between SVC nodes and the physical storagearrays
第13题:
Which of the following is most accurate in describing the required types of FCP zoningconsiderations when implementing a SAN Volume Controller (SVC)?()
第14题:
What is an advantage of IBM SAN Volume Controller (SVC) virtualization over an HP EnterpriseVirtual Array virtualization?()
第15题:
A customer plans to replace a McData 6140 core director with a Cisco MDS 9506. The storage is based on SVC with three DS5300 back-end storage systems. The storage resources are attached to the 6140 core while all servers are attached to edge switches. Linux, Windows and AIX servers use the SVC. Which of the following is a potential risk associated with this planned migration?()
第16题:
The following are new enhancements announced with SAN Volume Controller Version 6 EXCEPT()
第17题:
A customer plans to implement SVC as part of a solution and has concerns regarding the resilience of the SVC architecture. The correct response to this concern is that SVC().
第18题:
Which of the following describes an aspect of the SVC for XIV offering?()
第19题:
thereare no potential risks
the FCIDs of the servers must be changed
the SVC must be shut down during the migration
changing the FCIDs of storage resources will impact some servers
第20题:
in the place of the SVC
between the SVC and the hosts
between the SVC and the back-end disk storage
alongside the SVC,then the hosts should be mapped to both
第21题:
Easy Tier
SVC for XIV
deduplication
completely redesigned user interface
第22题:
DS5000 ,SVC and Storwize V7000
DS8000,SVC and Storwize V7000
DS8000,DS5000 and Storwize V7000
TS3500,ProtecTIER and Tivoli Storage Manager
第23题:
DS Hardware Management Console (HMC), because it manages ESS 800, DS6000, DS8000, and SVC storage servers
Tivoli Storage Productivity Center for Data, because it manages ESS 800, DS6000, DS8000, and SVC storage servers
Tivoli Storage Productivity Center for Replication, because it manages ESS 800, DS6000, DS8000, and SVC storage servers
External DS Hardware Management Console (HMC), because it manages ESS 800, DS6000, DS8000, and SVC storage servers
第24题: