第1题:
Companycom is migrating from a p690 to a p5 595 utilizing APV Virtual IO features. They have created their profiles for their two Virtual IO Servers. The first Virtual IO Server is installed and running. When trying to DLPAR the DVD/ROM the task fails on the HMC. What is the probable cause?()
第2题:
Companycom has several AS/400 servers in their IT infrastructure running V5R2 that they wish to consolidate. The customer wants to simplify their environment and install i5/OS on a p5 590 with 16 1.65GHz processors and 20 i5/OS partitions. The customer plans to use the Advanced Power Virtualization to share their storage, processors, and memory. What considerations and limitations should be reviewed with the customer before the purchase?()
第3题:
Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()
第4题:
A large customer is consolidating their pSeries systems onto a p5 590. They will have a requirement for a single device (disk, lun) to have multiple paths through different adapters in a single LPAR. The primary applications were written for AIX 5.2. Which of the following would be the recommended solution to satisfy this requirement?()
第5题:
The servers on your network run Windows Server 2008 R2. You are planning a two-node Hyper-V failover cluster with SAN storage, and 16 virtual machines (VMs). You plan to use quick migration. You need to place the maximum number of VMs on each logical unit number (LUN). You need to ensure that you can move individual VMs between cluster nodes without affecting other VMs. How many VMs should you place on each LUN?()
第6题:
Increase memory
Add more adapters
Increase both processors and adapters
Increase the number of processors by 20 - 30%
第7题:
Create LVM mirrors between LUNs
MPIO is necessary as the device driver
Use separate fibre adapters in the Virtual IO Server for each LUN
Virtual IO Server is a disk subsystem and must control the LUNs behind it
第8题:
From the HMC
From a NFS mount
From a FTP server
From any CD or DVD drive on another server
第9题:
2
3
4
5
第10题:
3
5
10
20
第11题:
APV key is not registered
Networking and DNS are not configured
/etc/hosts table on HMC is not configured
Virtual IO Server dose not support DLPAR
第12题:
Create two virtual adapters on the client, each one from a separate Virtual IO Server
Enable dead gateway detection on the client so that the network traffic can be rerouted
Have a spare network card on standby in the client in case the Virtual IO Server goes down
Create an etherchannel adapter on the client using one Virtual Ethernet adapter from two separate Virtual IO Servers
第13题:
How can virtual processors be differentiated from dedicated processors from a physical processor viewpoint?()
第14题:
Companycom is purchasing a 64-way p5 595. They have determined the location for the server is in a datacenter which does not have a raised floor. Which of the following would best meet the server requirements?()
第15题:
Companycom is planning for a 64-way p5 595. The plan is to use Virtual IO Servers and micropartitioning. What is the maximum number of partitions they can allocate?()
第16题:
Companycom tells the technical sales specialist that recent announcements state that virtual lan in the datacenter is the best option. The customer wants to use interpartition communication to save on adapters and increase performance. The systems are going to have shared and dedicated processor partitions. Some of the partitions will be running AIX 5.2 and some will be running AIX 5.3. The second p5 590 will be running a mixture of AIX 5.3 and Linux partitions with 2.6 kernel. What limitations of vlan/interpartition communication should be discussed with this customer?()
第17题:
What is the maximum number of primary partitions that can be created in a basic disk. ()
第18题:
Reallocate the Virtual IO Server disks to the user LPAR
Create a stripe-group within the Virtual IO Server to protect against disk failure
Reconfigure the user LPAR to use both locally owned disk and a Virtual SCSI disk
Create a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers
第19题:
The server must be installed into a location with a raised floor for optimum system cooling and cable management.
The server should be purchased as a p5 590 and then upgraded to a p5 595. This will eliminate the need for a raised floor environment.
The server should be purchased as 32-way p5 595 and then upgraded to a 64-way. This will eliminate the need for a raised floor environment.
The server can be installed into a location without a raised floor if an RPQ is obtained. It is a strong IBM recommendation for a raised floor, not a requirement.
第20题:
Resources cannot be shared with an i5 partition when it is put on a pSeries. The i5 partition needs its own 9411-100 tower because of IOP. V5R3 OS or later is required. There is a maximum of two partitions in a 590.
Resources cannot be shared between partitions when i5/OS is put on a pSeries. The i5 partition needs its own 9411-100 tower because of IOP. i5/OS can be at V5R2 or a V5R3. Currently only one i5 partition is allowed.
V5R3 is required for the i5 partitions. Virtual IO Server is not supported for the i5/OS partitions to share storage. Up to 10 i5 partitions per processor are allowed (a maximum of two processors for up to 20 partitions).
Processor and memory resources can be shared between AIX 5L, Linux and i5/os partitions. i5/OS needs to be at V5R3, and Virtual IO Server is not supported for the i5/OS partition to share storage. On a 1.65 GHz POWER5 p5 590 there is a maximum of one partition.
第21题:
one
four
eight
two
第22题:
Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet is supported on AIX 5L and Linux 2.5 and above.
Virtual Ethernet can be used within groups of shared OR groups of dedicated processor partitions, but not both simultaneously. Virtual Ethernet comes with AIX 5L, and is supported in AIX 5.2 or AIX 5.3 partitions, but not Linux.
Virtual Ethernet can be used in both shared and dedicated processor partitions. Virtual Ethernet can run in an AIX 5.3 or Linux 2.6 Kernel, but not AIX 5.2 partitions. Virtual Ethernet can only connect partitions within a single system.
Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet can connect partitions between systems if the HMC is shared between systems.
第23题:
128
254
320
640
第24题:
Dedicated processors are fractions of whole processors that are dedicated to a single partition.
Virtual processors are the whole number of concurrent operations that the operating system can use.
Virtual processors and not dedicated processors are processors used in Virtual IO Server partitions.
Virtual processors and dedicated processors are interchangeable concepts, both are whole physical processors used in virtual and dedicated LPARs.