Run lscfg -vl, and check the ROM levels
Run cfgmgr -v, and check the ROM levels
Run inventory scout, and check the installed levels
Run lslpp -l grep devices, and check the filesets installed
第1题:
Companycom wants to know how to keep track of the latest level of microcode for their p5 systems to stay current. What is the best way to monitor for new microcode?()
第2题:
Companycom is migrating from p670 systems running AIX 5.2 to p5 595 systems running AIX 5.3. They will be changing out only the system units. They will re-use the existing 61D drawers and adapters with the new p5 595 systems. What compatibility issue must be considered?()
第3题:
Companycom wants to deploy WebSphere in an HACMP environment, running on two servers in LPARs. These servers will also host the test and dev LPARs. The customer would like to use the test and dev resources to support an HACMP failover. What is the best way to accomplish this task?()
第4题:
Companycom is migrating their application that was built on AIX 4.3, to a new p5 590 system that is running AIX 5.3. The application was a 32-bit program. What will need to be done with the application to allow it to run on the new system?()
第5题:
An administrator plans to attach an IBM DS6000 and needs to know if the fibre channel adapter is at the latest firmware level. Which of the following is the fastest way for the administrator to determine the atest supported microcode level ()
第6题:
A system administrator is responsible for a vast and growing collection of dissimilar AIX systems. The verification of microcode levels and installation of new microcode is becoming increasingly unmanageable. What tool can be used to discover the existence of new microcode and automate the download and installation?()
第7题:
Company.com is adding a new I/O drawer to an existing p5-570 with four LPARs and wants to re-balance the network cards in the I/O drawers. What is the best way to accomplish this?()
第8题:
Add the devices as virtual adapters to a VIO server first,then add the I/O drawer and create the shared ethernet adapters
Power down the partitions,run the diag a command when the system is brought back up and reconfigure the network cards
Use the rmdev command to remove the devices,shut down the partitions and move the cads,then run the cfgmgr command after reboot
Detach the network cards,run rmdev on the devices and then dynamically reassign theadapters to the partitions and reconfigure
第9题:
lsgcl
lsrep
padmin_history
alog o t console
第10题:
APV features are not supported for some legacy POWER4 adapters
APV will require the most current maintenance level for AIX 5.2
APV features will require that legacy POWER4 adapters be updated with new microcode
The Virtual IO Server must run AIX 5.3 and the LPARs can run either AIX 5.2 or AIX 5.3
第11题:
Call Techline
Validate via DS6000 menu
Access IBM Storage Website
Contact the IBM Business Partner
第12题:
Use lquerypv to read the drive
Use lspv and look at PP Size value
Look on the outside of the drive itself
Use bootinfo to find the LTG on the drive
第13题:
A customer reports that error messages occasionally appear and quickly disappear. Which of thefollowing is the BEST place for a technician to begin troubleshooting this issue?()
第14题:
Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()
第15题:
An administrator suspects problems on a SCSI hard disk, but upon running diagnostics, no errors were found. What must be done to check the condition of the drive?()
第16题:
How does an administrator, logged in as padmin, check what commands have been recently run on the VIO server?()
第17题:
After rebooting the machine, Companycom notices that the machine is not performing as well as before. The applications are running slower, and their CPU utilization has increased. How can the customer check to see if a CPU was deallocated?()
第18题:
Which of the following commands should be used to check the settings for a new tty that was just set up as tty2?()
第19题:
Examine the section of the Health Check report given below: DBMS_HM.GET_RUN_REPORT(’HM_RUN_1061’) Run Name : HM_RUN_1061 Run Id : 1061 Check Name : Data Block Integrity Check Mode : REACTIVE Status : COMPLETED Start Time : 2007-05-12 22:11:02.032292 -07:00 End Time : 2007-05-12 22:11:20.835135 -07:00 Error Encountered : 0 Source Incident Id : 7418 Number of Incidents Created :0 Which two statements are true regarding the Health Check report?()
第20题:
Activate the Trial COD for the processors and run a test to verify outcome
Activate the On/Off COD for the processors and run a test to verify outcome
Use rmss to simulate the processor workload and run a test to verify outcome
Use rmps to simulate the processor workload and run a test to verify outcome
第21题:
REGEDIT
services.msc
Dxdiag
msconfig
第22题:
Run lscfg -vl, and check the ROM levels
Run cfgmgr -v, and check the ROM levels
Run inventory scout, and check the installed levels
Run lslpp -l grep devices, and check the filesets installed
第23题:
NIM
HMC
suma
invscout
第24题:
Run without recompiling on AIX 5.3
Relink to the 32-bit kernel in order to run the application
Recompile to run on AIX 5.3 because the libraries are in different locations
Recompile 32-bit applications because the compiler flags and versions have changed