Using ’diagmenu’ command, set fcs1 to Defined.
Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.
Using ’diagmenu’ command, set the fcs1 state to Defined
Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined
第1题:
A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark). They like the idea of being able to do SAN maintenance while not incurring downtime. If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()
第2题:
A cluster using IPAT via IP aliasing has four adapters. Normally there are several resource groups that have a total of four service IP labels. When two of the adapters fail, what happens?()
第3题:
Company.com has non-IBM fibre attached storage. The storage is connected to a node in the cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed. What feature of HACMP can be sued to assist with this issue?()
第4题:
A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()
第5题:
A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage. They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost. Which of the following storage solutions best satisfies the customer’s requirements?()
第6题:
You are designing a Hyper-V solution. You plan to virtualize an application server. The application server requires failover clustering that uses shared storage. You need to choose the correct storage solution. What should you choose?()
第7题:
One fibre channel switch
Two fibre channel switches
Two Ethernet cards
Nothing
第8题:
LPAR-A with 1Gb FC HBA and SAN connection
LPAR-B with 2Gb FC HBA and SAN connection
LPAR-C with 4Gb FC HBA and SAN connection
LPAR-D with 8Gb FC HBA and SAN connection
第9题:
Using ’diagmenu’ command, set fcs1 to Defined.
Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.
Using ’diagmenu’ command, set the fcs1 state to Defined
Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined
第10题:
Disk heartbeat
Error notification
Event notification
Application monitor
第11题:
Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAs
Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.
Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.
Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.
第12题:
Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solution
Add iSCSI cards to the servers and direct attach them to a DS300 dual controller model
Use clustered NAS solution with redundant gigabit network connections
Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model
第13题:
A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()
第14题:
A system has two configured fibre channel cards, one of which, fsc0, has failed and must be replaced. Which command should an administrator use to remove the card device and attached child devices?()
第15题:
A customer has a small SAN with both Linux and Windows servers attached to a DS4300 storage server through a redundant fabric. Which of the following is the most important consideration to ensure that this configuration would function properly?()
第16题:
A cluster administrator has been asked to install HACMP on two nodes with the following hardware: -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage. In order to eliminate single points of failure,the administrator should first add which of the following:()
第17题:
A medium-sized company with 500 employees has a rapidly growing storage infrastructure with clustered mail, database, and file and print core business applications running on six servers. Using current direct attached SCSI storage pools to each server leads to inefficient utilization of storage space.They also have a backup device attached to each server. They want to consolidate their storage and backup infrastructure into a scalable, high availability and high performance solution. The customer’s top priorities are performance, cost, and availability. Which of the following backup solutions best satisfies the customer requirements?()
第18题:
Would 10/100 Ethernets work as well?
Should there be eight fibre channel adapters?
Should there be an async adapter for heartbeat?
Will all LPARs need access to a common fibre channel tape drive?
第19题:
rmdev -Rdl fcs0
rmdev -cdl fcs0
rmdev -cdl fscsi0
rmdev -Rdl fscsi0
第20题:
an additional 1GB RAM to each node.
Another bootable mirrored disk drive.
A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.
Nothing,because this is a viable cluster solution with no single points of failure.
第21题:
A DS4000 SAN with flash copy enabled for volume mirroring
An iSCSI solution with dedicated backup server with SCSI attached tape library
A NAS solution with SCSI direct attached tape library with dedicated backup network
A DS4000 SAN with fibre channel attached tape library solution with dedicated backup zone
第22题:
The SAN is offline
Fiber channel switch
Multiple failed drives in the SAN
HBA
第23题:
The resource group containing the IP labels changes to an offline state.
The IP service labels of the failed adapters relocate the surviving adapters.
Nothing because the resource groups wait for the adapters to become active again.
The resource groups containing the IP labels of the failed adapters migrate to a backup node.
第24题:
The utilization of interswitch links between the redundant switches
The enablement of the multi-OS Storage Partitioning feature on the DS4300
Selection of 50u multi-mode Fibre to ensure 2Gb operation
The RAID level of the array on the DS4300 storage server