单选题A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()AUsing ’diagmenu’ command, set fcs1 to Defined.BUsing ’oem_setup

题目
单选题
A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()
A

 Using ’diagmenu’ command, set fcs1 to Defined.

B

 Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.

C

 Using ’diagmenu’ command, set the fcs1 state to Defined

D

 Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined


相似考题
参考答案和解析
正确答案: A
解析: 暂无解析
更多“单选题A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()A  Using ’diagmenu’ command, set fcs1 to Defined.B  Using ’oem_s”相关问题
  • 第1题:

    A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()

    • A、Would 10/100 Ethernets work as well?
    • B、Should there be eight fibre channel adapters?
    • C、Should there be an async adapter for heartbeat?
    • D、Will all LPARs need access to a common fibre channel tape drive?

    正确答案:B

  • 第2题:

    A cluster using IPAT via IP aliasing has four adapters. Normally there are several resource  groups that have a total of four service IP labels. When two of the adapters fail, what happens?()  

    • A、 The resource group containing the IP labels changes to an "offline" state.
    • B、 The IP service labels of the failed adapters relocate the surviving adapters.
    • C、 Nothing because the resource groups wait for the adapters to become active again.
    • D、 The resource groups containing the IP labels of the failed adapters migrate to a backup node.

    正确答案:B

  • 第3题:

    Company.com has non-IBM fibre attached storage. The storage is connected to a node in the  cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed.  What feature of HACMP can be sued to assist with this issue?()  

    • A、 Disk heartbeat
    • B、 Error notification
    • C、 Event notification
    • D、 Application monitor

    正确答案:B

  • 第4题:

    A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()

    • A、Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAs
    • B、Move the existing physical network and storage adapters to the new system and virtualize the I/O using a  single VIO Server.
    • C、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC  connectors and dual HBAs.
    • D、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC  connectors and the other with dual HBAs.

    正确答案:C

  • 第5题:

    A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()

    • A、Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solution
    • B、Add iSCSI cards to the servers and direct attach them to a DS300 dual controller model
    • C、Use clustered NAS solution with redundant gigabit network connections
    • D、Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model

    正确答案:D

  • 第6题:

    You are designing a Hyper-V solution. You plan to virtualize an application server. The application server requires failover clustering that uses shared storage. You need to choose the correct storage solution. What should you choose?()

    • A、Two child partitions with volumes mounted from an iSCSI SAN
    • B、Two host servers with Fibre Channel-attached storage enabled for Cluster Shared Volumes (CSVs)
    • C、Two host servers with iSCSI-attached storage enabled for Cluster Shared Volumes (CSVs)
    • D、Two child partitions with VHDs stored on an iSCSI SAN

    正确答案:A

  • 第7题:

    单选题
    A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()
    A

    One fibre channel switch

    B

    Two fibre channel switches

    C

    Two Ethernet cards

    D

    Nothing


    正确答案: A
    解析: 暂无解析

  • 第8题:

    单选题
    A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()
    A

    LPAR-A with 1Gb FC HBA and SAN connection

    B

    LPAR-B with 2Gb FC HBA and SAN connection

    C

    LPAR-C with 4Gb FC HBA and SAN connection

    D

    LPAR-D with 8Gb FC HBA and SAN connection


    正确答案: B
    解析: 暂无解析

  • 第9题:

    单选题
    A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()
    A

     Using ’diagmenu’ command, set fcs1 to Defined.

    B

     Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.

    C

     Using ’diagmenu’ command, set the fcs1 state to Defined

    D

     Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined


    正确答案: B
    解析: 暂无解析

  • 第10题:

    单选题
    Company.com has non-IBM fibre attached storage. The storage is connected to a node in the  cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed.  What feature of HACMP can be sued to assist with this issue?()
    A

     Disk heartbeat

    B

     Error notification

    C

     Event notification

    D

     Application monitor


    正确答案: B
    解析: 暂无解析

  • 第11题:

    单选题
    A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()
    A

    Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAs

    B

    Move the existing physical network and storage adapters to the new system and virtualize the I/O using a  single VIO Server.

    C

    Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC  connectors and dual HBAs.

    D

    Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC  connectors and the other with dual HBAs.


    正确答案: A
    解析: 暂无解析

  • 第12题:

    单选题
    A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()
    A

    Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solution

    B

    Add iSCSI cards to the servers and direct attach them to a DS300 dual controller model

    C

    Use clustered NAS solution with redundant gigabit network connections

    D

    Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model


    正确答案: A
    解析: 暂无解析

  • 第13题:

    A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()

    • A、LPAR-A with 1Gb FC HBA and SAN connection
    • B、LPAR-B with 2Gb FC HBA and SAN connection
    • C、LPAR-C with 4Gb FC HBA and SAN connection
    • D、LPAR-D with 8Gb FC HBA and SAN connection

    正确答案:B

  • 第14题:

    A system has two configured fibre channel cards, one of which, fsc0, has failed and must be replaced. Which command should an administrator use to remove the card device and attached child devices?()

    • A、rmdev -Rdl fcs0
    • B、rmdev -cdl fcs0
    • C、rmdev -cdl fscsi0
    • D、rmdev -Rdl fscsi0

    正确答案:A

  • 第15题:

    A customer has a small SAN with both Linux and Windows servers attached to a DS4300 storage server through a redundant fabric. Which of the following is the most important consideration to ensure that this configuration would function properly?()

    • A、The utilization of interswitch links between the redundant switches
    • B、The enablement of the multi-OS Storage Partitioning feature on the DS4300
    • C、Selection of 50u multi-mode Fibre to ensure 2Gb operation
    • D、The RAID level of the array on the DS4300 storage server

    正确答案:B

  • 第16题:

    A cluster administrator has been asked to install HACMP on two nodes with the following  hardware:   -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage.  In order to eliminate single points of failure,the administrator should first add which of the following:()   

    • A、 an additional 1GB RAM to each node.
    • B、 Another bootable mirrored disk drive.
    • C、 A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.
    • D、 Nothing,because this is a viable cluster solution with no single points of failure.

    正确答案:B

  • 第17题:

    A medium-sized company with 500 employees has a rapidly growing storage infrastructure with clustered mail, database, and file and print core business applications running on six servers.  Using current direct attached SCSI storage pools to each server leads to inefficient utilization of storage space.They also have a backup device attached to each server.  They want to consolidate their storage and backup infrastructure into a scalable, high availability and high performance solution.  The customer’s top priorities are performance, cost, and availability.   Which of the following backup solutions best satisfies the customer requirements?()

    • A、A DS4000 SAN with flash copy enabled for volume mirroring
    • B、An iSCSI solution with dedicated backup server with SCSI attached tape library
    • C、A NAS solution with SCSI direct attached tape library with dedicated backup network
    • D、A DS4000 SAN with fibre channel attached tape library solution with dedicated backup zone

    正确答案:D

  • 第18题:

    单选题
    A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()
    A

    Would 10/100 Ethernets work as well?

    B

    Should there be eight fibre channel adapters?

    C

    Should there be an async adapter for heartbeat?

    D

    Will all LPARs need access to a common fibre channel tape drive?


    正确答案: A
    解析: 暂无解析

  • 第19题:

    单选题
    A system has two configured fibre channel cards, one of which, fsc0, has failed and must be replaced.  Which command should an administrator use to remove the card device and attached child devices?()
    A

    rmdev -Rdl fcs0

    B

    rmdev -cdl fcs0

    C

    rmdev -cdl fscsi0

    D

    rmdev -Rdl fscsi0


    正确答案: B
    解析: 暂无解析

  • 第20题:

    单选题
    A cluster administrator has been asked to install HACMP on two nodes with the following  hardware:   -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage.  In order to eliminate single points of failure,the administrator should first add which of the following:()
    A

     an additional 1GB RAM to each node.

    B

     Another bootable mirrored disk drive.

    C

     A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.

    D

     Nothing,because this is a viable cluster solution with no single points of failure.


    正确答案: D
    解析: 暂无解析

  • 第21题:

    单选题
    A medium-sized company with 500 employees has a rapidly growing storage infrastructure with clustered mail, database, and file and print core business applications running on six servers.  Using current direct attached SCSI storage pools to each server leads to inefficient utilization of storage space.They also have a backup device attached to each server.  They want to consolidate their storage and backup infrastructure into a scalable, high availability and high performance solution.  The customer’s top priorities are performance, cost, and availability.   Which of the following backup solutions best satisfies the customer requirements?()
    A

    A DS4000 SAN with flash copy enabled for volume mirroring

    B

    An iSCSI solution with dedicated backup server with SCSI attached tape library

    C

    A NAS solution with SCSI direct attached tape library with dedicated backup network

    D

    A DS4000 SAN with fibre channel attached tape library solution with dedicated backup zone


    正确答案: C
    解析: 暂无解析

  • 第22题:

    单选题
    The staff is not able to access a database server.  The server has an ’Operating System not found’error and is set to boot from a fiber channel SAN. All other database servers are set to boot from the SAN and access the same switch and data as this database server. Which of the following is the MOST likely cause of the problem?()
    A

    The SAN is offline

    B

    Fiber channel switch

    C

    Multiple failed drives in the SAN

    D

    HBA


    正确答案: B
    解析: 暂无解析

  • 第23题:

    单选题
    A cluster using IPAT via IP aliasing has four adapters. Normally there are several resource  groups that have a total of four service IP labels. When two of the adapters fail, what happens?()
    A

     The resource group containing the IP labels changes to an offline state.

    B

     The IP service labels of the failed adapters relocate the surviving adapters.

    C

     Nothing because the resource groups wait for the adapters to become active again.

    D

     The resource groups containing the IP labels of the failed adapters migrate to a backup node.


    正确答案: B
    解析: 暂无解析

  • 第24题:

    单选题
    A customer has a small SAN with both Linux and Windows servers attached to a DS4300 storage server through a redundant fabric. Which of the following is the most important consideration to ensure that this configuration would function properly?()
    A

    The utilization of interswitch links between the redundant switches

    B

    The enablement of the multi-OS Storage Partitioning feature on the DS4300

    C

    Selection of 50u multi-mode Fibre to ensure 2Gb operation

    D

    The RAID level of the array on the DS4300 storage server


    正确答案: A
    解析: 暂无解析