CoD and PCI hot-plug
DLPAR and Active Memory Sharing
Hot node add and hot node repair
D.ynamic processor failure and processor instruction retry
第1题:
A customer is evaluating PowerVM and VMware to run a data warehouse application. Which feature of PowerVM should be highlighted as a differentiator?()
第2题:
A customer has a Power 770 running an SAP ERP workload on AIX 7. It has a single partition with 12 cores and 48GB of memory and the CPU is underutilized at 46% with 1000 users. Memory utilization is at 80%. The number of users will increase to 1700, increasing memory utilization by 37%. Which of the following supports this requirement?()
第3题:
A customer has shut down an LPAR after using DLPAR to add or remove processor and memory resources. When the partition is reactivated, the desired changes are missing. What action, or sequence of actions, will immediately and permanently solve this problem?()
第4题:
A customer is considering procuring HP servers with Virtual Server Environment (VSE) to consolidate servers and dynamically move resources between partitions. How can the technical sales representative position PowerVM as the solution to virtualize this server environment?()
第5题:
Which of the following features of Active Memory perform a regular check and cleanup of the status of DIMMs?()
第6题:
PowerVM supports shared servers compared to VSE
PowerVM supports shared processors and memory compared to VSE
PowerVM supports shared processors, memory and I/O compared to VSE
PowerVM supports DLPAR without a reboot and supports dedicated I/O compared to VSE
第7题:
IBM i Edition
Express Edition
Standard Edition
Enterprise Edition
第8题:
PowerVM Standard Edition on POWER6 hardware
PowerVM Standard Edition with POWER5 hardware
PowerVM Enterprise Edition with POWER6 hardware
PowerVM Enterprise Edition with POWER5 hardware
第9题:
PowerVM offers partition mobility.
PowerVM can virtualize network and SAN resources.
PowerVM supports multiple operating systems running concurrently.
PowerVM allows an LPAR to use activated cores and memory without limitation.
第10题:
Etherchannel and trunking
Network Interface Backup and Etherchannel
Shared Ethernet Adapter (SEA) Failover and Etherchannel
Network Interface Backup and Shared Ethernet Adapter failover
第11题:
Adapter A in slot 1, adapter B in slot 4 and hot-add adapter C in slot 3
Adapter A in slot 1, adapter B in slot 3 and hot-add adapter C in slot 2
Adapter A in slot 2, adapter B in slot 4 and hot-add adapter C in slot 3
Adapter A in slot 3, adapter B in slot 1 and hot-add adapter C in slot 4
第12题:
rg1 is configured with a delayed fallback timer
Settling time policy has not been configured for rg1
Node1 does not have sufficient resources to support rg1
Node2 is the first in the ’Default Node Priority’ list for resource group rg1
第13题:
Companycom wants to deploy WebSphere in an HACMP environment, running on two servers in LPARs. These servers will also host the test and dev LPARs. The customer would like to use the test and dev resources to support an HACMP failover. What is the best way to accomplish this task?()
第14题:
A customer is consolidating seven IBM i partitions onto a POWER7 system, using VIO Server to virtualize resources.Which of the following PowerVM editions is appropriate for this customer?()
第15题:
A customer has a key application running in a logical partition on a POWER5 system. The customer wants the ability to run the application with minimal down time using Live Partition Mobility. Which of the following is the minimum PowerVM edition and hardware configuration that will support the customer requirement?()
第16题:
During a planning session, it is determined that a three node cluster (Node ’A’, Node ’B’, and Node ’C’) will meet the customer’s application needs. Node ’B’ will be a hot-standby fallover node for both Node ’A’ and Node ’C’ resource groups. A serial network for this cluster will require which connections?()
第17题:
A server has two PCI-X buses with four Active PCI-X slots. Slots 1 and 2 are on the first PCI-X bus (100MHz) and slots 3 and 4 are on the second PCI-X bus (133MHz). The customer requires you to install adapter A and adapter B on day one. After the server has been installed and configured, the server must be running 24 by 7 with no downtime. Three months later, adapter C needs to be hot added. All the adapters are 64-bit and capable of speeds up to 133MHz. The customer’s priority is to have no downtime, and performance is secondary. Based on the information provided, into which slots should adapters A and B be installed in and later into which slot would adapter C be hot-added?()
第18题:
Reserve Capacity on Demand
Utility Capacity on Demand
Capacity Upgrade on Demand
Uncapped Capacity on Demand
第19题:
A single serial network between Node ’A’ and Node ’B’ and Node ’C’
A point-to-point link between Node ’A’ and Node ’C’,and Node ’B’ and Node ’C’
A serial network between Node ’A’ and Node ’C’,and a serial network between Node ’B’ and Node ’C’
A point-to-point link between Node ’A’ and Node ’B’ Node ’B’ and Node ’C’ and Node ’A’ ad Node ’C’
第20题:
PowerVM Lx86
PowerVM Express Edition
PowerVM Standard Edition
PowerVM Enterprise Edition
第21题:
Hot install
Hot add
Plug and play
Hot plug
第22题:
clstop
halt -q
shutdown -F
stopsrc -s cluster
第23题:
Run the test and dev LPARs in an uncapped mode
Activate COD resources if a failover should occur
Use DLPAR to move resources between the test and dev and the HACMP LPAR
Stop the test and dev environments, bring up new profile for HACMP failover