288GB
360GB
432GB
728GB
第1题:
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system’s administrator has decided to mirror two drives for the operating system. Which of the following is the maximum space the administrator will have remaining to use for data when using RAID 0?()
第2题:
An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array. When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()
第3题:
A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()
第4题:
A system administrator needs to maintain 1.2TB of storage for a database server. There are six 250GB drives available in the server for storage space. Which of the following RAID configurations would be the BEST choice given that performance and fault tolerance are important factors?()
第5题:
Which of the following BEST describes RAID 5?()
第6题:
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()
第7题:
RAID 5 is data striping across all drives.
RAID 5 is data striping with a dedicated parity drive.
RAID 5 is striped sets with two sets of parity striped across all drives.
RAID 5 is striped sets with parity striped across all drives.
第8题:
RAID 1 across drive pairs totaling 3 pairs
RAID 5 across all 6 drives
RAID 10 across all 6 drives
RAID 0 across all 6 drives
第9题:
292GB
438GB
584GB
728GB
第10题:
Replace the drive
Restore the drive from backup
Reboot the server
Reconfigure RAID 5 to RAID 10
第11题:
Restart the installation via WDS.
Shut down the server and check that all RAID drives are connected properly.
Restart the installation from CD and press F6 to install RAID drivers.
Go into the BIOS and set all RAID drives to compatibility mode
第12题:
288GB
360GB
432GB
728GB
第13题:
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()
第14题:
A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()
第15题:
A server has six drives of equal size attached to a RAID controller. Which of the following RAID levels would provide the FASTEST performance?()
第16题:
An administrator installs a new server with five 146GB drives and implements RAID 5 for hardware redundancy.How much disk space will be available for the OS, tools and regular files?()
第17题:
There is a power outage and all servers are shut down properly by the uninterruptible power supply(UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors,16GB of memory, and a RAID 5 array with 10 drives. Which of the following is the MOST likely cause?()
第18题:
An administrator has been instructed to add four additional drives to a server configured with RAID5. The server is using 146GB drives for the data. Without changing the configuration, how much additional data space would be available if the administrator purchased 300GB drives and added them to the existing array?()
第19题:
438GB
584GB
900GB
1200GB
第20题:
Memory
SCSI backplane
SCSI drives
Motherboard
第21题:
A failed RAID controller
Two failed processors
Two failed sticks of memory
Two failed drives
第22题:
Memory
SCSI backplane
SCSI drives
Motherboard
第23题:
288GB
360GB
432GB
728GB
第24题:
146GB
438GB
584GB
730GB