Memory
SCSI backplane
SCSI drives
Motherboard
第1题:
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array.How much usable disk space will this array have?()
A.288GB
B.360GB
C.432GB
D.728GB
第2题:
A system has five 80GB disk drives and has a requirement to store 300GB of data. Which disk configuration will provide fault tolerance while still meeting data storage requirements?()
第3题:
A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()
第4题:
A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()
第5题:
A server has six drives of equal size attached to a RAID controller. Which of the following fault tolerant RAID levels would allow the maximum amount of data to be stored? ()
第6题:
A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status? ()
第7题:
An xSeries specialist monitors a customer’s server that has poor performance. The customer is running an x365 with a ServeRAID 6i controller with write-back cache turned on and ten 15K rpm drives in a RAID-5 array. It is a mission-critical server and must have a redundant storage system. Performance tests indicate that the Average Disk sec/Transfer exceeds 20 ms. Which of the following is the lowest-cost method to increase the throughput?()
第8题:
x366
x255
x346
x455
第9题:
RAID implementation
Disk-to-disk replication
Server-to-server clustering
Hot site replication
第10题:
Break mirror array
Replace cache battery
Replace hot standby
Restore from backup
Replace defective hard drives
第11题:
JBOD
RAID-5
RAID-0
RAID-1
第12题:
OS:3 Drives,RAID 1 with hot spare;Files:5 Drives,RAID 5 with hot spare
OS:2 Drives,RAID 1;Files:6 Drives,RAID 1
OS:2 Drives,RAID 0;Files:6 Drives,RAID 5
OS:2 Drives,RAID 1;Files:6 Drives,RAID 5 with hot spare
第13题:
A. RAID 1 +0
B. RAID 5
C. RAID 0
D. RAID 1
第14题:
A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status?()
第15题:
Which of the following offers the MOST redundancy for a system but is also very costly? ()
第16题:
A server has six drives of equal size attached to a RAID controller. Which of the following RAID levels would provide the FASTEST performance?()
第17题:
An administrator installs a new server with five 146GB drives and implements RAID 5 for hardware redundancy.How much disk space will be available for the OS, tools and regular files?()
第18题:
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()
第19题:
A customer has a need for an xSeries server for an application requiring 12GB memory with the capacity of up to 20GB. The HDD configuration needs to be as follows: (1)Two drives RAID-1 for the operating system (2)Five drives for Data in a RAID-5 configuration with one Hot-Spare (3)All drives have to be internal. Which of the following will satisfy the requirements for the application?()
第20题:
292GB
438GB
584GB
728GB
第21题:
288GB
360GB
432GB
728GB
第22题:
Memory
SCSI backplane
SCSI drives
Motherboard
第23题:
Memory
SCSI backplane
SCSI drives
Motherboard
第24题:
RAID 5
RAID 1+0
RAID 0
RAID 1